Available Fuel: Biomass

DHL Series Biomass Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal, biomass

DHL Series Coal Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal...

DHX Coal Fired CFB Steam Boiler

Capacity: 35 – 75 t/h
Working Pressure: 1.25 – 5.3 Mpa
Outlet Temperature: 194 – 485 ℃
Industries: Chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Biomass particles

DZL Series Biomass Fired Steam Boiler

Capacity: 2 – 20 t/h
Working Pressure: 1 – 2.5 Mpa
Outlet Temperature: 170 – 225 ℃
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Nature gas, coke oven gas...

SZS Series Gas / Oil Fired Steam Boiler

Capacity: 10 - 100 t/h
Working Pressure: 1.0 – 2.5 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Available Fuel: Nature gas, coke oven gas...

WNS Series Gas Fired Steam Boiler

Capacity: 1 – 20 t/h
Working Pressure: 0.7 – 2 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

PROCEDURE FOR DETERMINING THE THEORETICA

2014-7-24 · boiler design, (c) breeching length, configuration, insulation, (d) stack height, material of construction, exposure. A coefficient of friction in the stack shall be taken as 0.016 for all types of stack construction, in accordance with the ASHRAE 1972 Handbook of Fundamentals. Be aware that the selection of the proper

Specification 36. Heating, hot and cold water, steam an

2012-12-10 · electrical engineering works. The Specification covers the installation of heating, hot and cold water, steam and gas services for buildings other than dwellings. It is a revision of the former Standard Specification (M&E) No. 3, dated 1988, and Guidance Notes for Users, dated 1990. 2. When this Specification is used in connection with a

Benchmark Boiler Application Guide - AER

2017-11-27 · ASHRAE standards recommend sizing equipment with a minimum of over sizing for maximum system efficiency. A multiple MFC boiler installation matches any load fluctuation from 0 to without overshoot. AERCO subscribes to and recommends the methods used by ASHRAE to develop required loads and sizes.

Weil-McLain PFG Series Specification Sheet - ManualsL

Weil-McLain Boiler Specification Sheet. PFG Series Boiler pdf manual download. Weil-McLain PFG Series Specification Sheet Appliance Energy Conservation Act or ASHRAE 90.1. G. Boiler(s) shall be manufactured by ISO 9001 registered company to conform. to Section IV of the ASME Boiler and Pressure Vessel Code. 1.

Consulting - Specifying Engineer | Resources for boile

2014-4-18 · Consulting - Specifying Engineer - Perhaps the most widely accepted boiler and pressure code in the world is the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel ASHRAE: This society The engineer and owner need to establish the emission requirements up-front when the design and specification is prepared

Building Codes and Indoor Air Quality - US E

2014-8-14 · addition, ASHRAE Standard 62.1 for commercial buildings, and ASHRAE Standard 62.2 for residential buildings are consensus standards and represent the standard of practice for the building industry with respect to ventilation and indoor air quality. Provisions of

Life to Boilers Summa

2016-4-12 · Specification requirements or specification language stipulating a Design Life ‐‐ or that the plant/equipment shall be designed (or provided) to achieve a particular Design Life ‐‐ are not new to the boiler industry either in the United States or internationally.

ASHRAE Standard 90.1-2010 Increases Minimum Pip

American Society of Heating, Refrigerating, and Air Conditioning Engineers (ASHRAE) Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings and the International Energy Conservation Code (IECC) are the major energy design standards for new buildings in the United States. Most states or local jurisdictions have adopted some version of either Standard 90.1 or the

Consulting - Specifying Engineer | Boilers: Type

2013-3-22 · Applying the boiler in most efficient configuration is the responsibility of the consulting engineer. The table of boiler types included in this article is not intended to be complete, but only a reference to basic types and configurations available. Fabrication materials vary between manufacturers along with patented designs.

Boilers (industrial) Specifications | Engineering3

The boiler is designed for commercial or HVAC applications. Deaerator / Separator Deaerators are vessels in which boiler feedwater is heated under reduced pressure in order to remove dissolved air. Economizer Economizers are heat exchangers that transfer heat from the gases of combustion to the boiler

5.3102.19 Replacement of Steam Boiler | Standar

2019-9-4 · A higher water volume boiler will be selected to ensure elimination of condensate return tanks (see also SWS 5.3102.19 Replacement of Steam Boiler) Ensure longer life and improved durability of equipment. Ensure the ability/option to remove condensate return tanks