• Mon - Sun : 8:30am to 5:00pm

40 cfr part 63 subpart jjjjjj new small boilers

Available Fuel: Biomass

DHL Series Biomass Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal, biomass

DHL Series Coal Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal...

DHX Coal Fired CFB Steam Boiler

Capacity: 35 – 75 t/h
Working Pressure: 1.25 – 5.3 Mpa
Outlet Temperature: 194 – 485 ℃
Industries: Chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Biomass particles

DZL Series Biomass Fired Steam Boiler

Capacity: 2 – 20 t/h
Working Pressure: 1 – 2.5 Mpa
Outlet Temperature: 170 – 225 ℃
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Nature gas, coke oven gas...

SZS Series Gas / Oil Fired Steam Boiler

Capacity: 10 - 100 t/h
Working Pressure: 1.0 – 2.5 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Available Fuel: Nature gas, coke oven gas...

WNS Series Gas Fired Steam Boiler

Capacity: 1 – 20 t/h
Working Pressure: 0.7 – 2 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

INTERMEDIATE STATE PERMIT TO OPERA

2018-6-6 · The types of boilers in §63.11195(e) are not subject to 40 CFR Part 63, Subpart JJJJJJ: [§63.11195] 1) A gas-fired boiler as defined in §63.11237. [§63.l 1195(e)] Operational Limitation: The gas-fired boilers shall burn natural gas not combined within any solid fuels and burn fuel oil No. 2

SBEAP Boilers - Tenness

2014-3-21 · Referred to as the National Emission Standard for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers at Small/Area Sources (40 CFR Part 63, Subpart JJJJJJ), a copy of the rule is available at the Electronic Code of the Federal Register.

Boiler Area Source Rule "Boiler GACT" summary (40 CF

2011-3-28 · GACT: control of HAPs from biomass-fired and oil-fired boilers Boiler Area Source Rule "Boiler GACT" summary (40 CFR 63 subpart JJJJJJ) Source description Compliance Date (§63.11196) Existing sources subject to a work prac-tice/management practice standard of a tune-up to meet compliance with this final rule in the Federal No later than 1

40 CFR Part 60 - Subpart Dc - TCEQ

40 CFR Part 60 - Subpart Dc This page contains links to the rule text, requirements tables, and flowchart for this subpart. Standards of Performance for Small

Industrial, Commercial and Institutional Boilers at Are

2014-7-26 · Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary Federal Regulation • NESHAP, 40 CFR 63, Subpart JJJJJJ • Proposed rule published June 4, 2010 • Final rule published March 21, 2011 and reconsidered but not stayed New Small oil-fired (units with heat

Subpart Dc—Standards of Performance for Smal

2019-5-10 · Subpart Dc—Standards of Performance for Small Industrial-Commercial-Institutional Steam Generating Units. Subpart I Solid Waste Programs (CFR 40 Part 239 to 299) Landfills - Sanitary/C&D. Temporary boilers are not subject to this subpart. [72 FR 32759, June 13, 2007, as amended at 74 FR 5090, Jan. 28, 2009; 77 FR 9461, Feb. 16, 2012]

Air Toxics – NESH

40 CFR Part 63, Subpart XXXXXX To help facilities understand new requirements to reduce air emissions from Metal Fabrication and Finishing operations, the Iowa DNR Air Quality Bureau and the Iowa Air Emissions Assistance Program (IAEAP) at the University of Northern Iowa have developed important compliance assistance tools.

Existing - Large (≥ 10MMBtu/hr) Existing - Larg

2011-8-24 · Summary of Requirements for 40 CFR Part 63 Subpart JJJJJJ: NESHAP for Area Sources: Industrial, Commercial, and Institutional Boilers Task 1 Submit Initial Notifications Task 2 Comply with Work Practice Standards (§63.11201, Task 3 Meet Emission Limits New - Large (≥ 10MMBtu/hr) New - Large (≥ 10MMBtu/hr) Conduct performance (stack) test

Attachment 2 to the ATO – NESHAP Subpart JJJJJ

2016-11-2 · 40 CFR Part 63, Subpart JJJJJJ, as listed below. [40 CFR 63.11201(d)] 3. Work Practice, Emission Reduction Measures, and Management Practices . a. The Permittee must comply with each work practice standard, emission reduction measure, and management practice specified in the table below, which applies to the Permittee's boiler. An energy

New Source Performance Standards Subpart Dc fo

2016-2-26 · Each regulation has its own Subpart within Part 60. For example, regulations applicable to small boilers are found in Subpart Dc (Standards of Performance for Small Industrial-Commercial-Institutional Steam Generating Units). To obtain a copy of 40 CFR Part 60, Subpart Dc, go to, select "Laws, Regulations &

Air Toxics Standards for Boilers - gaa.o

2018-5-15 · 40 CFR Part 63 Subpart 6J Applies to an area source facility which emits or has potential to emit less than 10 tons per year (tpy) of any single HAP and less than 25 tpy of any combination of HAP. Expected to apply to about 183,000 boilers located primarily at commercial facilities (e.g., hotels, office