• Mon - Sun : 8:30am to 5:00pm

electric contrl valve for boiler economizer

Available Fuel: Biomass

DHL Series Biomass Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal, biomass

DHL Series Coal Fired Steam Boiler

Capacity: 20 – 75 t/h
Working Pressure: 1.25 – 5.4 Mpa
Outlet Temperature: 184 – 485 ℃
Industries: Power generation, heating, chemical, food, rubber.

Available Fuel: Bituminous coal...

DHX Coal Fired CFB Steam Boiler

Capacity: 35 – 75 t/h
Working Pressure: 1.25 – 5.3 Mpa
Outlet Temperature: 194 – 485 ℃
Industries: Chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Biomass particles

DZL Series Biomass Fired Steam Boiler

Capacity: 2 – 20 t/h
Working Pressure: 1 – 2.5 Mpa
Outlet Temperature: 170 – 225 ℃
Industries: Heating, chemical, food, tobacco, textile, printing and dyeing, feed, medicine, building material, wine, rubber, hospital.

Available Fuel: Nature gas, coke oven gas...

SZS Series Gas / Oil Fired Steam Boiler

Capacity: 10 - 100 t/h
Working Pressure: 1.0 – 2.5 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

Available Fuel: Nature gas, coke oven gas...

WNS Series Gas Fired Steam Boiler

Capacity: 1 – 20 t/h
Working Pressure: 0.7 – 2 Mpa
Outlet Temperature: 194 – 540 °C
Industries: Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

upgnet.com - LOG

WEB SUPPORT: 800-201-YORK (9675) or by Email at [email protected]

EnergyControl.com | HVAC and Building Automatio

EnergyControl.com is the number one Industrial source for low priced industrial controls such as temperature sensors, energy monitoring and power metering and sub-metering equipment, Variable Frequency Drives, lighting control, Belimo damper actuators and Belimo control valves for Heating Ventilation and Air Conditioning systems. We offer Quality Customer Service and Technical

Tekmar Boiler Controls

Home >> Boiler and Burner Controls >> Tekmar Boiler Controls Results You searched for : Tekmar Boiler Controls Results Displayed: 1 - 6 of 6

HVAC Valve Sizing In The "Real World" | Industria

2019-9-10 · A control valve is the single most important element in any fluid handling system. Selecting the proper valve will have great effect on the efficiency of a system. There are volumes of information on the science of valve sizing and fluid mechanics. To properly size a control valve, a design engineer would take into consideration the entire system; pumps, piping geometry

Heating, ventilation, and air conditioning

2019-9-12 · Heating, ventilation, and air conditioning (HVAC[1]) is the technology of indoor and vehicular environmental comfort. Its goal is to provide thermal comfort and acceptable indoor air quality. HVAC system design is a subdiscipline of mechanical engineering, based on the principles of thermodynamics, fluid mechanics and heat transfer

3-way valve | Grundf

2019-9-17 · The purpose of a 3-way control valve is to shut off water flow in one pipe while opening water flow in another pipe, to mix water from two different pipes into one pipe, or to separate water from one pipe into two different pipes. The 3-way valve is characterized by three ports A, B and C.

Belimo Actuators & Valves - HVAC Parts & Controls

Do not use this item for any installation or repair of potable water applications. This product does not comply with the "Safe Drinking Water Act," which requires that products meet low-lead standards in order to be used in systems providing water for human consumption (drinking or cooking).

Air Pollution Control Technology Fact Sheet - US E

2015-9-1 · boiler operating at 85% capacity requires approximately 17 m 3 ( 600 ft 3). For the same sized coal-fired boiler, the required catalyst is on the order of 42 m3 (1,500 ft3). (NESCAUM 2000). SCR is a proprietary technology and designs on large combustion units are site specific. Retrofit of SCR on an existing unit can increase costs by over 30%

VisionPRO™ 8000 Touchscreen Programmable Thermost

2012-1-17 · oil, electric and heat pumps for 1 heat, 1 cool systems. The TH8320 Thermostats provide temperature control for gas, oil, electric and heat pumps for up to 3 heat, 2 cool systems configure changeover valve for cool (O-factory setting) or heat (B). 4. L terminal is an input (system monitor) when the System mode is in the Heat, Off, Cool or Auto

HVAC Valve Sizing In The "Real World" | Industria

2019-9-10 · A control valve is the single most important element in any fluid handling system. Selecting the proper valve will have great effect on the efficiency of a system. There are volumes of information on the science of valve sizing and fluid mechanics. To properly size a control valve, a design engineer would take into consideration the entire system; pumps, piping geometry

Pressure Regulators - Valves - The Home Dep

This 1-1/4 in. water pressure reducing valve is This 1-1/4 in. water pressure reducing valve is designed to reduce incoming water pressure to protect plumbing systems and reduce water consumption for commercial industrial and residential applications. The easy maintenance assembly consists of a lead free brass body construction double union